| MATERIAL SAFETY DATA SHEET | PAGE 1 OF 2 | |
| U.S. DEPARTMENT OF LABOR | REVIEWED: 4/1/99 | |
| Abbrev. | ||
| COMPLIES WITH USDL SAFETY AND
HEALTH REGULATIONS (29 CFR
1910.1200) | ||
| SECTION 1: | MANUFACTURER: | PRODUCT IDENTIFICATION | |
| Amerex Corporation P.O. Box 81 Trussville, AL 35173-0081 |
Argon | ||
| EMERGENCY: Chemtrec:1-800-424-9300 Amerex: 1-205-655-3271 |
|||
| SECTION 2: HAZARDOUS
INGREDIENTS |
| % | *ACGIH ppm |
*OSHA ppm |
OTHER | |||||
| CHEMICAL NAME | CAS # | W/W | TLV | STEL | PEL | STEL | IDLH | |
| Argon | 7440-37-1 | 100 | NE | NE | NE | NE | NE | Simple asphyxiant |
| *NE = None
Established | ||||||||
| SECTION 3: PHYSICAL DATA |
| BOILING POINT: -185.9 degrees C. |
| VAPOR PRESSURE: Not
Applicable. Cylinder pressure will depend on volume of gas
contained. Determine internal pressure with a pressure gauge. |
| GAS DENSITY: (o degrees C) 1.784 kg/m3 |
| SOLUBILITY IN WATER: Soluble. 0.033 cm3/cm3water |
| SPECIFIC GRAVITY: Approximately 1.38. |
| PERCENT VOLATILE BY VOLUME: Not Applicable. |
| EVAPORATION RATE: Not Applicable. |
| pH: (1% solution) Not Applicable. |
| APPEARANCE & COLOR: This material is an odorless, compressed gas. |
| SECTION 4: FIRE AND EXPLOSION DATA |
| FLASH POINT: Not Applicable. |
| FLAMMABLE LIMITS: Not Applicable. |
| EXTINGUISHING MEDIA: Not normally ignitable. Use Water spray, Carbon Dioxide, Foam, Dry Chemical, Halon, any other Class "B" extinguishing agent. |
| SPECIAL FIREFIGHTING PROCEDURES:
Structural fire fighters must wear Self-Contained Breathing Apparatus and
full protective equipment. Keep unused cylinders cool using water spray.
When involved in a fire, this cylinder under pressure may rupture
violently causing a high pressure release of
gases. |
| MATERIAL SAFETY DATA SHEET | PAGE 2 OF 2 | |
| MANUFACTURER: AMEREX CORPORATION | DATE: 08-15-96 | |
| PRODUCT IDENTIFICATION: Argon | Abbrev. | |
SECTION 5: HEALTH HAZARD DATA THRESHOLD LIMIT VALUE: Not
Established. |
SECTION 6: REACTIVITY DATA STABILITY DATE:
Stable. |
SECTION 7: SPILL OR LEAK PROCEDURES SMALL SPILLS: All gases in this mixture
occur naturally in the environment. Will dissipate rapidly in well
vented areas. |
SECTION 8: SPECIAL PROTECTION INFORMATION RESPIRATORY PROTECTION: Not expected to be
needed. Maintain oxygen levels of minimum of 19.5% If below 19.5% oxygen,
use supplied air respiratory protection. HMIS: 1-0-0 NFPA: 1-0-0 |
SECTION 9: SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANDLING AND
STORAGE: Follow reasonable and safe practices. ANSI Z400.1-1993 FORMAT MSDS AVAILABLE ON REQUEST |